3-Phase Well Test Separator

3-Phase Well Test Separator

Al Shirawi 3 Phase Separator is a horizontal vessel fitted with technically advanced instruments and designed to efficiently separate well effluents into three phases. We have installed a one of a kind CSC testing facility in UAE and Middle East. This facility is offered to our customers who would like to get any structure tested and certified to CSC. 

AESCO offers varying well test packages and products like DNV/CSC skid mounted well test packages, storage tanks, oil well testing equipment etc. 3-phase well test separator comes under offshore package. The package is designed to offshore lifting standard DNV2.7-1 and CSC approved skid with crash frame for ease of rapid transportation to offshore or onshore worksites globally on container vessels.

Features and advantages:

  • Available in multiple configuration and pressure ratings to meet individual customer needs
  • Multiple safety valves to redirect flow in the event of over-pressurization
  • Bypass capabilities allow for maintenance, repairs, and replacements without having to shut in the well.
  • Pressure, temperature and sampling ports on inlet and outlet lines enable maximum measurement and sampling in all phases
  • Skid mounted for easy transportation
  • Option for having the vessel internally coated with suitable product for extended vessel life
  • Configured for addition of Hi-Lo pressure and Hi-Lo level alarm, shut down system on vessel
  • Equipped with explosion-proof fluorescent lights to meet Zone 1 requirement and 50 meters of armored power supply cable
  • The vessel internal components are designed such that they are easily removable and serviceable through manway.

General Specification

Equipment Type

Well testing 3-phase separator

Nominal Vessel Size

42” x 10 ft T/T , Horizontal

Maximum Working Pressure

1330 psi at 250 Deg F

Design Pressure

1440 psi at 122 Deg F

Design Temperature

-20 to 250 Deg F

Service condition

H2S/CO2

Material of construction

Shell

SA 516 Gr 70 N

Elliptical Heads

SA 516 Gr 70 N

Nozzles

SA 105, SA 350-LF2

Applicable Standard

Vessel
ASME Sec VIII, Div 1
NACE MR0175
ANSI B31.3 Class M (H2S)
CE, PED 97/23/EC

Skid
Lifting DNV -2.7-1
CSC/ISO 1496-1

 

Mechanical Specification


External Connections

Inlet

Gas Outlet

Oil Outlet

Water Outlet

Vent

All connections Fig 206 unions with ANSI 600 RF Flange

3” Female

4” Male

3” Male

2” Male

4” Male

 

 

Measuring Equipment

Gas

Oil

Water

  • Daniels Senior Orifice Meter 6”(5.761” ID) ANSI 600# RF Flange
  • Daniels Senior Orifice Meter 2”(5.761” ID) ANSI 600# RF Flange
  • 3-Pen static pressure/temperature and differential Barton pressure recorder

 

  • 2” & 1” Nu-Flo Turbine meters with MCII plus display
  • Pressure and Temperature sensing points
  • Calibrated 4L Shrinkage Tester
  • 1” Nu-Flo Turbine meters with MCII plus display
  • Pressure and Temperature sensing points

 

Control  Equipment

Gas

Oil

Water

  • 3“ Fail Open Pneumatic control valve with C1 Pressure Controller
  • 1” Fail Open Pneumatic control valve with C1 Pressure Controller

 

 

  • 3” Fail Closed Pneumatic control valve with L 3 level controller with displacer sight glass
  • 2” Fail Closed Pneumatic control valve with L 3 level controller with displacer sight glass

Safety Devise
2 x 3 “ x 4” Pilot operated Pressure Safety Valves mounted directly on independent vessel nozzles with 4 “ Vent line terminating to skid edge
1 x 3 “ x 4” pilot operated pressure safety valve mounted on oil inlet and vent line